Usage

<< Click to Display Table of Contents >>

RayVentory Scan Engine > 12.6 u4 > User Guide > Inventory Agent > Parameters 

Usage

Name and Property

Format

Description

Whitelist

usageWhitelist

Filename

The name of executable files that the usage agent will consider (if none are defined, all processes will be considered).

Example: \\outlook\.exe

Default value = \\winword\.exe;#\\powerpnt\.exe;#\\teams\.exe;#\\outlook\.exe

Disabled

usageDisabled

Boolean

If set to true, the usage metering is disabled. If set to false, usage metering will be actviated.

Example: false

Default value = true

Log file size

usageLogFileSize

Byte

The maximum logfile size in bytes for the usage metering log.

Example: 4000000

Enable session loggin

usageEnableSessionLogging

Boolean

Enables the logging of when the tracked processes are started and when they are ended.

Example: true

Session backup period

usageSessionBackupPeriod

Seconds

The interval in which the sessions are backed up to a cache file.

Example: 600

Usage upload period

usageUploadPeriod

Seconds

The interval in which the usage metering creates an .mmi file that can be uploaded by RVIA.

Example: 172800

Default value = 86400

finger1

Be aware:

An .mmi file will only be created when there is session data in the session cache file. If no session data exist, no .mmi file will be created.

Startup delay

usageStartupDelay

Seconds

The number of seconds that the tracking of processes will be delayed after the startup of the metering service.

Example: 300

Minimal run time

usageMinRunTime

Seconds

The time in seconds that a process must be running before it is considered by the usage metering.

Example: 60

Process update period

usageProcessUpdatePeriod

Seconds

How often the metering service will update the processes.

Example: 60