<< Click to Display Table of Contents >> RayVentory Scan Engine > 12.6 u4 > User Guide > Inventory Agent > Parameters Usage |
Name and Property |
Format |
Description |
||
---|---|---|---|---|
Whitelist usageWhitelist |
Filename |
The name of executable files that the usage agent will consider (if none are defined, all processes will be considered). Example: \\outlook\.exe Default value = \\winword\.exe;#\\powerpnt\.exe;#\\teams\.exe;#\\outlook\.exe |
||
Disabled usageDisabled |
Boolean |
If set to true, the usage metering is disabled. If set to false, usage metering will be actviated. Example: false Default value = true |
||
Log file size usageLogFileSize |
Byte |
The maximum logfile size in bytes for the usage metering log. Example: 4000000 |
||
Enable session loggin usageEnableSessionLogging |
Boolean |
Enables the logging of when the tracked processes are started and when they are ended. Example: true |
||
Session backup period usageSessionBackupPeriod |
Seconds |
The interval in which the sessions are backed up to a cache file. Example: 600 |
||
Usage upload period usageUploadPeriod |
Seconds |
The interval in which the usage metering creates an .mmi file that can be uploaded by RVIA. Example: 172800 Default value = 86400
|
||
Startup delay usageStartupDelay |
Seconds |
The number of seconds that the tracking of processes will be delayed after the startup of the metering service. Example: 300 |
||
Minimal run time usageMinRunTime |
Seconds |
The time in seconds that a process must be running before it is considered by the usage metering. Example: 60 |
||
Process update period usageProcessUpdatePeriod |
Seconds |
How often the metering service will update the processes. Example: 60 |