<< Click to Display Table of Contents >> RayPack Studio > 8.0 > Release Notes > What's New? > RayPack Resolved Issues |
•Reapplying filters on opened RCP projects now uses the current exclusion configuration. RPK-5017
•Fixed an issue with excluding registry keys from projects that had registry capturing turned off. RPK-5015
•Fixed issues with loading resources from multi-icon files in PackDesigner. RPK-5072
•Fixed a possible crash when opening MSI packages created with WISE Package Studio. RPK-5059
•Fixed an issue where subsequent changes to MST files could be ignored after the first save. RPK-4981
•Resolved crashes of PowerShell custom actions on 32-bit machines. RPK-5006 ZEN-28172
•Pinning of shortcuts to Windows 10/11 Start menu is now disabled if the shortcut is advertised. RPK-4876
•Resolved several issues with concurrent usage of multiple instances of RayPack, accessing the same project. RPK-4979
•Fixed issues with resolving of formatted arguments of Scheduled Tasks. RPK-4819 ZEN-24918
•Fixed possible exception when pasting a VBS content in the Custom Action wizard for inline script actions. RPK-4810
•Fixed a possible crash when invoking the Test menu for custom searches (AppSearch) for files, due to invalid filter string. RPK-4902
•Fixed an issue where INI files with empty property DirProperty were not visible in the UI. RPK-4976
•Fixed an issue where it was possible to add two identical target platform dependencies. RPK-3464
•Fixed an issue where cancelling MSIX builds could cause the application to stop responding. RPK-5029
•Fixed a possible exception when editing the same MSIX package script twice. RPK-5010
•Context menu Edit with… is now properly disabled if the source file dos not exist. RPK-4996
•Resolved a rare issue where opening a .ps1 file from the command line would not open the PackWrapper screen. RPK-4957
•Fixed incorrect behavior of the .ps1 editor where adding multiple transforms to an MSI file entry would separate them with a comma. PSADT requires semicolons as the correct way to separate them. RPK-4956
•Resolved issues with the PackWrapper wizard not adding installation entries for setups without command line arguments. RPK-4777
•Fixed an issue where PackBot could not be started on the target virtual machine if the project directory on the host machine is configured on a drive that is not available in the virtual environment. RPK-4985
•Resolved rare issues with repackaging not finishing properly due to corrupted RayPack profile files. RPK-4774 ZEN-23223
•Fixed an issue where PackBot sometimes failed to create the second snapshot after a reboot. RPK-5095
•Fixed issues with App-V 5 sequencing that could result in an error Unknown error during sequencing. RPK-5100
•Resolved issues with the Import-Transform command let which was not functioning properly for .rpmst files. RPK-4785
•Fixed issues with PowerShell command lets not working when called from RayPack MSIX package. RPK-4704
•Fixed incorrect selection of profiles in rpcmd.exe. RPK-4752 ZEN-22036
•Fixed possible NullReferenceException when deploying to SCCM/ECM. RPK-5045
•Fixed minor UI issues, especially on lower resolutions. RPK-3466 RPK-3479.