WMI Query

<< Click to Display Table of Contents >>

RayManageSoft Unified Endpoint Manager > 3.1 > User Guide > Applications > Package Details > Dependencies > Edit a Dependency 

WMI Query

It is also possible to define a Windows Management Instrumentation (WMI) query as a dependency for a package. In order to define a WMI query, WMI Query needs to be selected in the RULE FOR dropdown field.

 

EditDependency_WMIQuery

 

HARDWARE CLASS:  For example, Win32_IDEController for IDE  & SATA controllers.

HARDWARE PROPERTY: For example, DeviceID could be used as property for the Win32_IDEController class selected in the HARDWARE CLASS field.

CONDITION: The condition of the query can be defined using the dropdown menu and the value field. The dropdown menu offers the following options:

oEqual to: The result of the query must match the condition.

oGreater than: The result of the query must be greater or equal to the defined condition value.

oLess than: The result of the query must be less or equal to the defined condition value.

oNot equal to: The result of the query must not match the defined condition value.

 

After selecting one of the options in the CONDITION dropdown box, a related value needs to be entered into the value field.  For example, a value for a DeviceID can look like PIC18F2520.

 

For detailed information about WMI, refer to the Microsoft Windows Management Instrumentation page.