<< Click to Display Table of Contents >> RayManageSoft Unified Endpoint Manager > 3.1 u8 > User Guide > Appendix I: Preference Settings for Managed Devices > Alphabetical Listing of Preference Settings for Managed Devices UITimeoutWait |
Command-line | Registry
Determines the number of seconds that a RayManageSoft Unified Endpoint Manager installation agent dialog displays before timing out and automatically selecting the default response. The first dialog to time out will do so after the specified period (or never, if the time out period is set to 0 seconds). Subsequent dialogs will time out after a maximum of 60 seconds. For example, if the time out period is set to 300 seconds and the first dialog does time out after 300 seconds, subsequent dialogs will time out after 60 seconds.
For details about how this setting works in combination with other installation settings to determine appropriate reboot actions, see Reboot Options.
Values / Range: |
Integer greater than 0 (number of seconds) |
Default value: |
300 |
Command-line
Tool: |
Installation agent |
Example: |
-o UITimeoutWait=30 |
Registry
Installed by: |
Installation of RayManageSoft Unified Endpoint Manager on a managed device (Computer setting) |
User setting: |
HKEY_CURRENT_USER\SOFTWARE\ManageSoft Corp\ |
Computer setting: |
[Registry]\ManageSoft\Launcher\CurrentVersion |